KVV - Copper core PVC insulated PVC sheathed control cable
Ideal for weak-current control systems and areas with low-level magnetic field interference, the KVV cable ensures consistent functionality in electrical control networks. Featuring PVC insulation and a PVC outer jacket, it delivers solid protection against damp conditions, mechanical strain, and corrosive agents. It is widely employed in low-voltage power supplies and signal/control loop applications.
Product structure diagram

Application
Suitable for use in control, monitoring, and safeguarding loops operating at AC rated voltages Uo/U up to a maximum of 450/750V.


Properties
The cable carries a rated voltage Uo/U of 450/750V. For continuous operation, the maximum conductor temperature is limited to 70°C for standard PVC types, whereas cross-linked polyethylene variants may operate at up to 90°C. The lower ambient temperature limit is –40°C when permanently installed, and –15°C when subject to movement. As for bending radius, the minimum allowable value is 6 times the overall cable diameter for unarmoured constructions, and 12 times for armoured ones.
Packaging
Finished product + wooden barrel packaging

Technical index
|
Project |
Index |
||
|
General flame-retardant PVC |
Low smoke and low halogen PVC |
Low smoke halogen-free polyolefin |
|
|
Oxygen index% |
30-32 |
31-36 |
36-40 |
|
Smoke density ≤ |
600 |
300 |
Smoke 50, no flame 260 |
|
Hydrogen halide gas release maximum mg/g ≤ |
580 |
100 |
5 |
Main technical indicators of products
|
Project |
Technical index |
|
|||||||||||||||
|
DC resistance at 20℃ (MΩ.km ) |
Section |
0.5mm² |
0.75mm² |
1.0mm² |
1.5mm² |
2.5mm² |
4.0mm² |
6mm² |
10mm² |
||||||||
|
Cladding material |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
|
|
Class A/B |
|
|
24.5 |
24.8 |
18.1 |
18.2 |
12.1 |
12.2 |
7.41 |
7.56 |
4.61 |
4.7 |
3.08 |
3.11 |
1.83 |
1.84 |
|
|
Class R |
39 |
40 |
26 |
26.7 |
19.5 |
20 |
13.3 |
13.7 |
7.98 |
8.21 |
|
|
|
|
|
|
|
|
Testing voltage |
3000V/5min |
||||||||||||||||
|
Insulation voltage |
Compliant with national standards |
||||||||||||||||
|
Flame retardant performance |
Complies with the national standard GB/T18380-2001 |
||||||||||||||||
Cross linking performance indicators
|
Project |
Unit |
Performance index |
Performance indicator |
|
Air temperature |
°C |
200 ±3 |
GB/T 2951.21-2008 |
|
Processing condition load time |
Min |
15 |
|
|
Mechanical stress |
N/cm2 |
20 |
|
|
Maximum elongation under load |
% |
175 |
|
|
Maximum permanent elongation after cooling |
% |
15 |

Hot Tags: copper control cable, China copper control cable manufacturers, suppliers, factory, Aluminium Tape Shielded Cable, control cable, Copper Control Cable, FR XLPE Cable, Instrumentation And Control Cables, Kvv Cable