The KVV cable features a copper conductor with PVC insulation and an outer PVC sheath. It is mainly intended for permanent installation in industrial environments, serving applications such as monitoring systems, electrical measurement, signal transmission, and protective circuits. Its voltage rating covers up to 450/750V, with some variants supporting 0.6/1kV as well.
Cable Construction & Specifications
Conductor
Made of annealed copper, available in either solid or stranded configurations
Insulation & Sheath
PVC material is used for both the insulation around each core and the overall external jacket


Number of cores
Ranges from 2 to 61 cores, with 2 to 37 being the most common offering
Conductor cross-section
Available from 0.75 mm² up to 6 mm², with larger sizes possible depending on specific requirements
Voltage rating (U₀/U)
450/750V or 0.6/1kV

Application
Industrial automation systems and manufacturing facilities
Control circuits in power plants and electrical substations
Indoor permanent installations, including cable trenches and protective tubing
Operating Characteristics
Maximum conductor temperature: 70°C for continuous long-term operation
Installation ambient temperature: Should remain above 0°C unless preheating is applied
Minimum bending radius (unarmoured types): Typically 6 × cable outer diameter
Packaging
Finished product + wooden barrel packaging

Technical index
|
Project |
Index |
|
|
|
General flame-retardant PVC |
Low smoke and low halogen PVC |
Low smoke halogen-free polyolefin |
|
|
Oxygen index% |
30-32 |
31-36 |
36-40 |
|
Smoke density ≤ |
600 |
300 |
Smoke 50, no flame 260 |
|
Hydrogen halide gas release maximum mg/g ≤ |
580 |
100 |
5 |
Main technical indicators of products
|
Project |
Technical index |
|
|||||||||||||||
|
DC resistance at 20℃ (MΩ.km ) |
Section |
0.5mm² |
0.75mm² |
1.0mm² |
1.5mm² |
2.5mm² |
4.0mm² |
6mm² |
10mm² |
||||||||
|
Cladding material |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
Tin |
No-tin |
|
|
Class A/B |
|
|
24.5 |
24.8 |
18.1 |
18.2 |
12.1 |
12.2 |
7.41 |
7.56 |
4.61 |
4.7 |
3.08 |
3.11 |
1.83 |
1.84 |
|
|
Class R |
39 |
40 |
26 |
26.7 |
19.5 |
20 |
13.3 |
13.7 |
7.98 |
8.21 |
|
|
|
|
|
|
|
|
Testing voltage |
3000V/5min |
||||||||||||||||
|
Insulation voltage |
Compliant with national standards |
||||||||||||||||
|
Flame retardant performance |
Complies with the national standard GB/T18380-2001 |
||||||||||||||||
Cross linking performance indicators
|
Project |
Unit |
Performance index |
Performance indicator |
|
Air temperature |
°C |
200 ±3 |
GB/T 2951.21-2008 |
|
Processing condition load time |
Min |
15 |
|
|
Mechanical stress |
N/cm2 |
20 |
|
|
Maximum elongation under load |
% |
175 |
|
|
Maximum permanent elongation after cooling |
% |
15 |

Hot Tags: kvv cable, China kvv cable manufacturers, suppliers, factory, Armored Shielded Cable, Copper Braided Cable, Copper Tape Shielded Cable, Flexible PVC Cable, High Temperature Flexible Cable, SWA Control Cable